(Illustration by Gaich Muramatsu)
On Fri, Mar 31, 2000 at 01:33:41PM +0200, Alan Scheinine wrote: > Since the server seemed to be a mess, I started over using the > instructions in Chapter 13, Reinitializing Coda Servers after > a Disaster. Now the coda server runs, though as yet no directories > are mounted. But venus always fails on very computer on which > venus runs and uses the server. And example is shown below. > > # venus -init & > 13:24:59 /usr/coda/LOG setup for size 0x3420cb > 13:25:00 /usr/coda/DATA initialized at size 0xd0832c > 13:25:00 brain-wiping recoverable store > 13:25:01 loading recoverable store > 13:25:02 fatal error -- CommInit: RPC2_Init failed There is already another venus process running. `killall -9 venus' should fix that. I am pretty sure you will have to unmount the /coda partition before the new venus is really happy. > 13:25:02 Fatal Signal (11); pid 4947 becoming a zombie... > 13:25:02 You may use gdb to attach to 4947 And the reason for the venus hanging around is that we intentionally coerce them into an endless sleep. Jan.Received on 2000-03-31 10:33:49